Document RE-2026-0814 · Rev. 2.1 · Confidential
Project
Residential electrical & receptacle upgrade
Property
Single-story house, Job No. 14 — Austin, TX
Contractor
Ridgeway Electric LLC (TX Lic. TECL-28491)
Dates
08/12/2026 — 08/25/2026

Residential Electrical & Receptacle Upgrade

Working drawings and notes for replacing receptacle devices, routing branch circuits, and updating the load-center layout for a private residence.

1. Project data sheet

Baseline data for estimate and installation. Owner: private. Contractor: Ridgeway Electric LLC, Austin, TX.

Building typeSingle-story dwelling, approx. 1,290 sq ft
Service120/240 V, single-phase, 200 A main breaker
Load centerMain panel in hallway (NEMA 1, bolt-on / plug-on breakers)
GroundingEquipment grounding conductor system; grounding electrode at utility room
Scope summaryReceptacle replacement, added outlets, circuits protected per NEC GFCI/AFCI rules
Codes & standardsNEC 2023 (NFPA 70), IRC, UL-listed devices and cable
Engineer of recordJames R. Mitchell, P.E.
Lead electricianMichael T. Brooks

2. Floor plan (Drawing FP-01)

Rooms: Foyer, Kitchen, Living Room, Bedroom 1, Bedroom 2, Bathroom, Hallway, Utility. Dimensions in feet-inches.

FP-01. Schematic floor plan of a single-story U.S. residence, top view, dimensions in feet
Fig. 1. FP-01 — schematic floor plan (top view). Reference for receptacle layout. © Ridgeway Electric LLC · James R. Mitchell, P.E. · 08/12/2026
1 / 3
RE-2026-0814 · Electrical layout

3. Electrical network layout (Drawing EL-01)

Branch circuits from the main panel: lighting, general receptacles, kitchen small-appliance, bathroom GFCI.

Receptacles (Circuit A) Lighting (Circuit B) Kitchen power (Circuit C) Bathroom / wet locations
EL-01. Schematic electrical network and receptacle layout over the house plan
Fig. 2. EL-01 — branch-circuit layout and receptacle points. © Ridgeway Electric LLC · James R. Mitchell, P.E. · 08/14/2026
General receptacles: 20 A branch circuits with combination AFCI/GFCI protection where required by NEC. Bathrooms: GFCI-protected 20 A circuits. Kitchen small-appliance: two or more 20 A circuits. Conductors: NM-B (Romex) 12 AWG copper (receptacles) / 10 AWG copper (range / cooktop).

4. Site photos — receptacles

Taken 08/18/2026. Device standard: NEMA 5-15R (Type B). Files PH-03 and PH-04 filed with the site inspection report.

PH-03. Duplex NEMA 5-15 receptacle and rocker switch on living-area wall, Job No. 14
Fig. 3. PH-03 — duplex receptacle and switch, living area. Photo: Michael T. Brooks · Job No. 14 · 08/18/2026
2 / 3
RE-2026-0814 · Scope & schedule
PH-04. Kitchen receptacle group above countertop at Job No. 14
Fig. 4. PH-04 — receptacle group above kitchen countertop. Photo: Michael T. Brooks · Job No. 14 · 08/18/2026

5. Scope of work

  1. Remove existing receptacles; inspect device boxes
  2. Install / replace NM-B copper cable runs per Drawing EL-01
  3. Assemble load center: breakers, neutrals, equipment grounds
  4. Install NEMA 5-15R devices (living areas) and WR/GFCI where required (bath, utility)
  5. Label circuits; insulation resistance and polarity / ground tests
  6. Final walkthrough with completion certificate and drawing set

6. Receptacle schedule

Living room6 duplex outlets · mounting height 12 in. AFF
Kitchen8 countertop outlets + dedicated cooktop / range circuit
Bedrooms4 duplex outlets each at headboard and desk
Bathroom1–2 GFCI outlets outside tub/shower zone
Foyer / hallway2 outlets + service receptacle at the panel
Utility2 WR/GFCI outlets for pumps and equipment
Engineer of record
James R. Mitchell, P.E.
Date: 08/25/2026
Lead electrician
Michael T. Brooks
Date: 08/25/2026